596
Primus
PN: PRW14                    
Construction
High grade spun aluminum reflector (14”/356 mm dia.), and aluminum mounting arm (1/2” NPT), with stainless steel mounting hardware. Globes are formed with glass.
Lamping
Operates with Cree™ LED (15W max.), compact fluorescent (32W max.), metal halide (70W max.), and incandescent (150W max.), light sources. Specify 3000K, 3500K or 4000K CCT for LED systems.

Note: LED systems operate with 120-277V supply voltage only.
LED modules do not require a socket, and are wired directly to the integral driver.
Incandescent and metal halide systems use a medium base socket (E26).
Incandescent systems are compatible with a 120V supply voltage only.

Diffuser
Globe: clear and prismatic, elongated, glass globes are available.

Note: LED systems are compatible with prismatic globes only.
G3 is used with 100IN, 32CF, and 15LED max.
Only prismatic globes are compatible with LED systems.

Options
Wire Guard: a steel, chrome-plated wire guard is available for lamp protection against light projectiles, wildlife, and serves as a vandal deterrent.
Ballast / LED Driver
Ballasts and LED drivers are electronic, and available for integral and remote mounting, indoor or outdoor.
The LED source is controlled by an advanced electronic driver that delivers consistent power.
Ballast are integral and electronic. They are efficient with a high power factor greater than 90%, and quiet with an “A” sound rating.
Surge Suppressor
All 120V, 277V, and universal voltage fixtures are protected by a 6kV surge suppressor.
Dimming
The LED dimming option is the 0-10V type, with pulse width modulation (PWM), and current-sinking control.
CF dimming options include the Mark 7 ® (0-10V), Mark 10 ® (line voltage), DALI (addressable), or Ecosystem ®.

Note: Use a current-sinking dimming system (by others) for LED dimming.
The dimming option is not available with 347V systems, or for outdoor CF applications.
Compatibility of this product is not guaranteed with all control systems.

Emergency
For LED systems, integral and remote emergency back-ups are available, in the standard temperature and cold temperature types.
For CF systems, remote emergency back-ups are available, in the standard temperature and cold temperature types.

Note: The emergency option is available with 120-277V systems only.
The test switch and indicator light would be remote.
EM Integral LED: (min. operating temp. +5C/+40F).
EMR Remote LED: (20 ft. / 6.096 m max. distance from EM to LED; min. operating temp. +5C/+40F; dry location mounting).
EMC Integral LED Cold Pack: (min. operating temp. -20C/-4F).
EMCR Remote LED Cold Pack: (20 ft. / 6.096 m max. distance from EM to LED; min. operating temp. -20C/-4F).
EMR Remote CF: (7 ft. / 2.134 m max. distance from EM to lamp; min. operating temp. +5C/+40F; dry location only).
EMCR Remote CF Cold Pack: (7 ft. / 2.134 m max. distance from EM to lamp; min. operating temp. -20C/-4F).
Finish
Available in brushed, anodized, and powder-coated finishes. All finishes, including the powder-coats, are applied to the outside and inside of the fixture. For the complete collage, see the “Finishes and Diffusers” chart.
Custom and RAL finishes are available by special order.
Mounting
Mount onto a flat wall, directly over a standard 4” electrical junction box.
Custom conduits are available.
Follow the installation instructions, and adhere to your local electrical code.
Compliances
QPS-C/US, or UL-C/US certified to UL1598 standards. Rated IP23 for dry to wet locations, indoor and outdoor.
The Consultants Europe (CE) listing is available upon request.