Login
Sign Up
Since 1923
593
Maxximus Wall
PN: MXW11                  
Construction
High grade spun aluminum reflector (11”/279 mm dia.), cast aluminum guard, and aluminum mounting arm (1/2” NPT), with stainless steel mounting hardware.
Lamping
Operates with Cree™ LED (15W max.), compact fluorescent (32W max.), metal halide (70W max.), or incandescent (150W max.). Specify 3000K, 3500K or 4000K CCT for LED systems.

Note: LED systems operate with 120-277V supply voltage only.
LED modules do not require a socket, and are wired directly to the integral driver.
Incandescent and metal halide systems use a medium base socket (E26).
Incandescent systems are compatible with a 120V supply voltage only.

Diffuser
Globe: clear and prismatic, elongated, glass globes are available.

Note: LED systems are compatible with prismatic globes only.

Ballast / LED Driver
Ballasts and LED drivers are electronic, and available for integral and remote mounting, indoor or outdoor.
The LED source is controlled by an advanced electronic driver that delivers consistent power.
Ballast are integral and electronic. They are efficient with a high power factor greater than 90%, and quiet with an “A” sound rating.
Surge Suppressor
All 120V, 277V, and universal voltage fixtures are protected by a 6kV surge suppressor.
Dimming
The LED dimming option is the 0-10V type, with pulse width modulation (PWM), and current-sinking control.
CF dimming options include the Mark 7 ® (0-10V), Mark 10 ® (line voltage), DALI (addressable), or Ecosystem ®.

Note: Use a current-sinking dimming system (by others) for LED dimming.
The dimming option is not available with 347V systems, or for outdoor CF applications.
Compatibility of this product is not guaranteed with all control systems.

Emergency
For LED and CF systems, integral and remote emergency back-ups are available, in the standard temperature and cold temperature types.

Note: The emergency option is available with 120-277V systems only.
EM Integral LED: (min. operating temp. +5C/+40F)
EMR Remote LED: (20 ft. / 6.096 m max. distance from EM to LED; min. operating temp. +5C/+40F; dry location mounting)
EMC Integral LED Cold Pack: (min. operating temp. -20C/-4F)
EMCR Remote LED Cold Pack: (20 ft. / 6.096 m max. distance from EM to LED; min. operating temp. -20C/-4F)
EM Integral CF: (min. operating temp. +5C/+40F)
EMR Remote CF: (7 ft. / 2.134 m max. distance from EM to lamp; min. operating temp. +5C/+40F; dry location only)
EMC Integral CF Cold Pack: (min. operating temp. -20C/-4F)
EMCR Remote CF Cold Pack: (7 ft. / 2.134 m max. distance from EM to lamp; min. operating temp. -20C/-4F)
The test switch and indicator light would be remote.

Finish
Maxximus is available in TMS specialty brushed, and powder-coated finishes; see the “Finishes and Diffusers” chart.
Custom RAL finishes are available by special order.

Note: Textured finishes are applied to all areas of the reflector.
Mounting
Mount on a flat wall, directly onto a standard 4" electrical junction box.
Follow the installation instructions, and adhere to your local electrical code.
Compliances
QPS-C/US, or UL-C/US certified to UL1598 standards. Rated IP55 for dry to damp locations, indoor and outdoor.
The Consultants Europe (CE) listing is available upon request.