Login
Sign Up
Since 1923
591
Hailey Wall / configure
PN: HYW10                    

Please log in to configure this product.

Project:
New Project
Date:
Type:
Qty:
RAL #:

Freight/Crate/RAL charges may apply. Contact TMS Lighting 1-866-793-1174 or e-mail.
Print Configuration
Save Configuration
Contact Local Rep

Specifications are subject to change without notice.

Version 1.3

Location
I
Indoor
n/a
O
Outdoor
n/a
Lamping
150IN
150W incandescent
n/a
26CF
26W PL-T
n/a
32CF
32W PL-T
n/a
42CF
42W PL-T
n/a
70MH
70W MH (E-17)
n/a
15LED
15W LED
n/a
LED CCT (color temperature)
----
None
n/a
30K
3000K
n/a
35K
3500K
n/a
40K
4000K
n/a
Voltage
120
120V
n/a
277
277V
n/a
347
347V
n/a
Ballast / Driver
----
None
n/a
WM
Wall Mount (integral)
n/a
N1
Remote Indoor Mount (NEMA 1)
n/a
N4
Remote Outdoor Mount (NEMA 4)
n/a
Finish
AN
Anodized (bright)
n/a
BR
Brushed Aluminum
n/a
F05
White
n/a
F08
Midnight Blue
n/a
F09
Pewter
n/a
F10
Fire Red
n/a
F13
Forest Green
n/a
F14
Sunshine Yellow
n/a
F15
Matte Black
n/a
F16
Gloss Black
n/a
F18
Flat Aluminum
n/a
F19
Mirror Silver
n/a
F21
Architectural Bronze
n/a
F24
Melted Platinum (textured)
n/a
F25
Melted Gold (textured)
n/a
F26
Melted Copper (textured)
n/a
F31
Silver Metallic
n/a
F33
Pyrite Bronze
n/a
RAL
RAL Custom Color (specify)
n/a
Dimming
----
None
n/a
DIM
CF Dimming: Advance Mark 10
n/a
DIMV
CF Dimming: Advance Mark 7 (0-10V)
n/a
DIMD
CF Dimming: Advance DALI
n/a
DIME
CF Dimming: Lutron Ecosystem
n/a
DIML
LED Dimming (0-10V, current-sinking)
Use a current-sinking dimming system (by others) with this option.
n/a
Emergency
----
None
n/a
EM
Integral CF
(min. operating temp. +5C/+40F)
n/a
EMC
Integral CF cold pack
(min. operating temp. -20C/-4F)
n/a
EM
Integral LED
(min. operating temp. +5C/+40F)
n/a
EMC
Integral LED cold pack
(min. operating temp. -20C/-4F)
n/a
EMR
Remote CF
(7 ft. / 2.134 m max. distance from EM to lamp; min. operating temp. +5C/+40F; dry location only)
n/a
EMCR
Remote CF cold pack
(7 ft. / 2.134 m max. distance from EM to lamp; min. operating temp. -20C/-4F)
n/a
EMR
Remote LED
(20 ft. / 6.096 m max. distance from EM to LED; min. operating temp. +5C/+40F; dry location mounting)
n/a
EMCR
Remote LED cold pack
(20 ft. / 6.096 m max. distance from EM to LED; min. operating temp. -20C/-4F)
n/a
Globe
----
None
n/a
G1
Clear, elongated globe
n/a
G3
Prismatic, elongated globe
n/a
Wire Guard
----
None
n/a
W10
10" Wire Guard
n/a
Hailey Wall / Notes
PN: HYW10                    

NOTES:

Control Systems — Compatibility of this product is not guaranteed with all control systems. For 0-10V dimming signal wire, use a minimum 18AWG cable.

LED Circuits — LED fixtures should be installed on a dedicated circuit. If a relay switch is required, use a solid state type. A mechanical relay could induce a surge of 10-30 times above normal.

Lead Times — This product is manufactured to order. Please contact your local sales representative for the current lead time.

Specifications and availability are subject to change.

Installation should only be performed by a qualified electrical contractor, and in accordance with national and local safety, building, and electrical codes.

Hailey Wall / details
PN: HYW10                    
Construction
High grade spun aluminum reflector (10" / 254 mm dia.), and aluminum conduit (1/2" NPT), with stainless steel mounting hardware.
Lamping
Operates with compact fluorescent (42W max.), incandescent (150W max.), metal halide (100W max.), or Cree™ LED (19W max.). Incandescent and metal halide models use a medium base socket (E26). Specify 3000K, 3500K or 4000K CCT LED.
Ballast / LED Driver
Ballasts are integral and electronic. They are efficient with a high power factor greater than 90%, and quiet with an "A" sound rating.

The LED source is controlled by an advanced, integral, electronic driver that delivers consistent power.

Surge Suppressor
All 120V, 277V, and universal voltage fixtures are equipped with a 6kV surge suppressor.
Emergency
For CF systems, an optional, integral, canopy-mounted, emergency back-up is available in either the standard temperature or cold temperature version.

For LED systems, integral and remote mount emergency back-ups are available, in either the standard temperature or cold temperature version.

Note: The test switch and indicator light would be remote.

Options
Wire Guard: a steel, chrome-plated wire guard is available for lamp protection, which also serves as a vandal deterrent.
Dimming
The LED dimming option is the 0-10V type, with current-sinking control.

Note: Use a current-sinking dimming system (by others) for LED dimming. Compatibility is not guaranteed with all control systems.

Finish
Select from brushed, anodized, and powder-coated finishes; see the Finishes and Diffusers chart. Custom and RAL finishes are available by special order.
Mounting
Mount directly to a standard 4" electrical junction box.
Follow the installation instructions, and adhere to your local electrical code.
Compliances
Rated IP23 for dry to damp locations, indoor and outdoor. Complies with UL, QPS, CSA and CSA-US standards. The Consultants Europe (CE) listing is available upon request.
details
notes