Login
Sign Up
Since 1923
542
Raj 1 / configure
PN: RJ1                      

Please log in to configure this product.

Project:
New Project
Date:
Type:
Qty:
RAL #:

Freight/Crate/RAL charges may apply. Contact TMS Lighting 1-866-793-1174 or e-mail.
Print Configuration
Save Configuration
Contact Local Rep

Specifications are subject to change without notice.

Version 1.3

Mounting
SM
Surface Mount
n/a
BM
Burial Mount - 48" (121cm) below grade
n/a
Height
10
120" OAH (305cm), 95" ht. (241cm) Clearance
n/a
12
144" OAH (366cm), 119" ht. (302cm) Clearance
n/a
14
168" OAH (426cm), 143" ht. (363cm) Clearance
n/a
16
192" OAH (426cm), 167" ht. (424cm) Clearance
n/a
Lamping
150IN
150W incandescent
n/a
42CF
42W PL-T
n/a
57CF
57W PL-T
n/a
100MH
100W MH (E-17)
n/a
175MH
175W MH (E-17)
n/a
19LED
19W LED
n/a
32LED
32W LED
n/a
LED CCT (color temperature)
----
None
n/a
30K
3000K
n/a
35K
3500K
n/a
40K
4000K
n/a
Voltage
120
120V
n/a
277
277V
n/a
347
347V
n/a
Pole Finish
F05
White
n/a
F07
Zeus Brown
n/a
F08
Midnight Blue
n/a
F09
Pewter
n/a
F10
Fire Red
n/a
F13
Forest Green
n/a
F15
Matte Black
n/a
F16
Gloss Black
n/a
F18
Flat Aluminium
n/a
F19
Mirror Silver
n/a
F21
Architectural Bronze
n/a
F31
Silver Metallic
n/a
F32
Bronze Metallic
n/a
F33
Pyrite Bronze
n/a
RAL
RAL Custom Color (specify)
n/a
Reflector Finish
OO
Same finish
n/a
AN
Anodized
n/a
CO
Solid Copper (brushed, with a clear coat)
n/a
SS
316L Stainless Steel (brushed)
n/a
Globe
----
None
n/a
G10
Prismatic, elongated, large globe
n/a
LNS
Clear, flat lens
n/a
Emergency
----
None
n/a
EM
Integral CF
(min. operating temp. +5C/+40F)
n/a
EMC
Integral CF cold pack
(min. operating temp. -20C/-4F)
n/a
EM
Integral LED
(min. operating temp. +5C/+40F)
n/a
EMC
Integral LED cold pack
(min. operating temp. -20C/-4F)
n/a
Receptacle
----
None
n/a
GF1
120V GFI receptacle with in-use cover (lock by others)
n/a
Photocell
----
None
n/a
PC
Photocell
n/a
Raj 1 / Notes
PN: RJ1                      

NOTES:

Control Systems — Compatibility of this product is not guaranteed with all control systems. For 0-10V dimming signal wire, use a minimum 18AWG cable.

LED Circuits — LED fixtures should be installed on a dedicated circuit. If a relay switch is required, use a solid state type. A mechanical relay could induce a surge of 10-30 times above normal.

Lead Times — This product is manufactured to order. Please contact your local sales representative for the current lead time.

Specifications and availability are subject to change.

Installation should only be performed by a qualified electrical contractor, and in accordance with national and local safety, building, and electrical codes.

Raj 1 / details
PN: RJ1                      
Construction
The pole is manufactured from 4.5” OD extruded aluminum, with a one-piece, spun aluminum base cover. The reflector is 19.62” diameter spun aluminum, with a clear or prismatic glass globe diffuser.
Lamping
Operates with integral Cree™ 32W LED, compact fluorescent (57W max.), metal halide (175W max.), and incandescent (150W max.) sources.

Note:
Incandescent systems are compatible with a 120V supply voltage only.
Integral LED systems are available with 120-277V supply only. Only CF and MH systems are available with a 347V supply.
Raj 1 is designed to operate with an E-17 metal halide lamp. Incandescent and metal halide systems use a medium base lamp socket (E26). A lamp socket is installed with CF systems. LED modules are wired directly to the integral driver, and do not require a lamp socket.
LED sources are supplied, not lamps.
Diffuser
The prismatic, glass globe increases the area of coverage uniformity, and provides protection for the light source. The size of globe depends on the lamp installed.
Lens: The flat, clear glass lens protects the light source from dirt, and also serves as a diffuser, for a slightly increased area of coverage.

Note: Choose either the globe or the lens, not both.

Ballast / LED Driver
Ballasts are integral and electronic. They are efficient with a high power factor greater than 90%, and quiet with an "A" sound rating.
The LED source is controlled by an advanced, integral electronic driver that delivers consistent power.
Surge Suppressor
All 120V, 277V, and universal voltage LED luminaires are equipped with an integral, 6kV surge suppressor.
Options
Photocell: Switches the luminaire ON at dusk, and OFF at dawn .
Ground Fault Indicator: A GFI receptacle could be installed to prevent a short-circuit from occurring in the line.

Note: The ground fault indicator receptacle is available with a 120V supply only. The lock would be provided by others.

Emergency
An integral, emergency back-up is available, maintaining a power supply to the luminaire in case of a power interruption. A cold pack is available for variable climates.

Note: The emergency back-up option is available to systems with 120-277V supply only. The test switch and indicator light would be remote.
Integral CF or LED: (min. operating temp. +5C/+40F)
Integral CF or LED with cold pack: (min. operating temp. -20C/-4F)

Finish
The pole is available in several TMS polyester powder-coated finishes.The reflector may be anodized aluminum, brushed solid copper, brushed 316L stainless steel, or the same finish as the pole. See the “Finishes and Diffusers” chart.

Note: Brushed copper is protected with a clear coat, yet patina will form over time with exposure to the elements.

Mounting
Direct burial and surface-mount configurations are available. See the installation instructions for mounting details, and adhere to the local electrical code.

Note: A base cover is provided for surface mounting only.

Compliances
Rated IP55 for use in dry to wet, indoor and outdoor locations. Complies with UL, QPS, CSA and CSA-US standards. The Consultants Europe (CE) listing is available upon request.
details