Login
Sign Up
Since 1923
119
Avero 1
PN: AV1                        
Construction
The pole is manufactured with 4.5” OD extruded aluminum, with a one-piece, spun aluminum base cover. The reflector is 16” diameter spun aluminum, with a prismatic, glass globe diffuser.
Lamping
Operates with Cree™ LED (15W max.), compact fluorescent (32W max.), metal halide (100W max.), and incandescent (150W max.) sources.

Note: Luminaire is designed to operate with an E-17 metal halide lamp.
Integral LED systems use 120-277V supply voltage, and are not compatible with 347V. Incandescent systems are compatible with a 120V supply voltage only. Only CF and MH systems are available with a 347V supply.
Incandescent and metal halide systems use a medium base lamp socket (E26). A lamp socket is installed with CF, MH and INC systems. LED modules are wired directly to the integral driver, and do not require a lamp socket.
Only integrated LED sources are supplied, not lamps.
Diffuser
The globe diffuser is formed with prismatic glass, providing wide area coverage.

Note: The G3 globe is used with 100IN, 32CF, and 15LED max.

Ballast / LED Driver
Ballasts are integral and electronic. They are efficient with a high power factor greater than 90%, and quiet with an "A" sound rating.
The LED source is controlled by an advanced, integral electronic driver that delivers consistent power.
Surge Suppressor
All 120V, 277V, and universal voltage LED luminaires are equipped with an integral, 6kV surge suppressor.
Emergency
An integral, emergency back-up is available, maintaining a power supply to the luminaire in case of a power interruption. A cold pack is available for variable climates.

Note: The emergency back-up option is available to systems with 120-277V supply only.
The test switch and indicator light would be installed remotely.
Integral CF or LED: (min. operating temp. +5C/+40F)
Integral CF or LED with cold pack: (min. operating temp. -20C/-4F)

Options
Photocell: Switches the luminaire ON at dusk, and OFF at dawn .
Wire Guard: Chrome-plated type for outdoors, protects the light source from debris.
Ground Fault Indicator: A GFI receptacle could be installed to prevent a short-circuit from occurring in the line.

Note: The ground fault indicator receptacle is available with a 120V supply only. The lock would be provided by others.

Finish
Available in several TMS standard, premium, polyester powder-coated, and custom RAL finishes. The reflectors may also be brushed solid copper or brushed 316L stainless steel. See the “Finishes and Diffusers” chart.

Note: Brushed copper is protected with a clear coat, yet patina will form over time with exposure to the elements.

Mounting
Direct burial and surface-mount configurations are available. See the installation instructions for mounting details, and adhere to your local electrical code.

Note: A base cover is provided for surface mounting only.

Compliances
Rated IP55 for use in dry to wet, indoor and outdoor locations. Complies with UL, QPS, CSA and CSA-US standards. The Consultants Europe (CE) listing is available upon request.
facts