Login
Sign Up
Since 1923
167
Phantom 5
PN: 3005PH                  
Construction
Steel frame, stem and ceiling canopy, with a cylindrical, UV-stabilized acrylic diffuser. Available in 2 sizes: 61” (1.549 m), and 75” (1.905 m) height, by 8” (203 mm) in diameter.
Lamping
Operates with linear fluorescent (2x 54W T5 HO max.), or Cree™ LED (112W max.) light sources. Specify 3000K, 3500K, or 4000K CCT for LED systems.
An optional 35W MH (CDM R111) or Cree™ 15W LED downlight is available, which would project the same CCT as the primary light source.

Note: Lamp sockets are installed for the fluorescent and metal halide lamps. LED modules do not require a lamp socket, and are wired directly to the driver.

Downlight
An optional Cree™ 15W LED or 35W MH (CDM R111) downlight is available, which would project the same CCT as the primary light source.

Note: When LED is the primary source, only the LED downlight is available. With a fluorescent primary source, either the LED or metal halide downlight is available.

Diffuser
The cylindrical diffuser is formed with UV-stabilized, opal-white acrylic, with a glossy finish.
Ballast / LED Driver
An advanced, electronic driver delivers consistent power to the LED source.
Ballasts are efficient with a high power factor greater than 90%, and quiet with an “A” sound rating.
Surge Suppressor
All 120V, 277V, and universal voltage fixtures are equipped with a 6kV surge suppressor.
Dimming
Fluorescent dimming options include the Mark 7 ® (0-10V), Mark 10 ® (line voltage), DALI (addressable), or Ecosystem ®.
The LED dimming option is the 0-10V, current-sinking type.

Note: Use a current-sinking dimming system (by others) with this option.
The dimming option is available with 120-277V supply voltage only.
The compatibility of this product is not guaranteed with all control systems.

Emergency
For LED and fluorescent systems, a remote mount emergency back-up is available, in the standard temperature type.

Note: The emergency option is available to systems with 120-277V supply voltage only.
The LED emergency back-up is available only when the 15W LED (DLED) downlight option is selected.
The test switch and indicator light would be remote.
Remote LED: (20 ft. / 6.096 m max. distance from EM to LED; min. operating temp. +5C/+40F; dry location)
Remote CF: (7 ft. / 2.134 m max. distance from EM to lamp; min. operating temp. +5C/+40F; dry location)

Finish
Select from premium plated, and polyester powder-coated finishes; see the “Finishes and Diffusers” chart.
Custom RAL finishes are available by special order.
Mounting
Mount indoor to a flat ceiling, directly over a standard 4” electrical junction box.
Specify the length of stem, from 12” (305 mm) to 120” (3.048 m).
The ceiling slope adapter keeps the pendant hanging vertically, correcting up to a 15° maximum slope.
Follow the installation instructions, and adhere to the local electrical code.

Note: The ceiling slope adapter may be required to comply with the local seismic/earthquake code.

Compliances
QPS-C/US, or UL-C/US certified to UL1598 standards. Rated IP20 for dry, indoor locations.
The Consultants Europe (CE) listing is available upon request.
facts